Uniflair Small Room Cooling

Uniflair Small Room Cooling

Uniflair Small Room Cooling

se.com

High-Performance Cooling

Units for Small Technological

Rooms and Edge Cooling

Applications (5-20 kW)

Uniflair Small Room Cooling

Schneider Electric: Your Partner in Sustainable Data Center Cooling

At Schneider Electric, we are committed to providing innovative and sustainable solutions that help organizations reduce their environmental impact and operational costs.

Our Uniflair Room Cooling units are designed with eco- efficiency in mind, utilizing advanced technologies to minimize energy consumption while maintaining peak performance.

Choose Your Cooling

Technology

Chilled Water units (SDCV-SUCV): Designed to work with a centralized chilled water plant, offering

efficient and scalable cooling solutions for large data centers and facilities.

Direct Expansion Air Cooled units (SDAV-SUAV): Highly efficient mechanical cooling systems,

ideal for small and medium-sized data centers. The units can be coupled with wide range of

remote air-cooled condensers (CAP) and employ to the latest generation of compressors.

Schneider Electric offers a variety of cooling technologies to suit your specific

needs:

3 Uniflair Small Room Cooling

Compact, Efficient, Reliable

Cooling Solutions

Uniflair Small Room Cooling provides a wide range of air intake and delivery configurations

to suit different needs:

Raised Floor Environments: The downflow configuration efficiently distributes cold air into

the floor void, while hot air can be drawn from the bottom or the front.

Server Rooms Without Raised Floors: The upflow configuration is ideal, drawing in hot air

from the front and delivering cold air upwards, either directly into the room or through

the false ceiling.

FLEXIBLE SOLUTIONS

FOR ANY ENVIRONMENT

In critical and edge applications, our cooling system is designed to minimize power

consumption dedicated to cooling the IT load. By optimizing floor space, Uniflair Small

Room Cooling units allow for maximum power allocation to IT equipment and ample

room for IT racks.

With full frontal accessibility and no need for lateral clearance, these units can be

installed in close proximity to each other, reducing the space required for cooling and

expanding the area available for your IT equipment.

MAXIMIZE IT LOAD

AND SAVE SPACE

Uniflair Small Room Cooling units are designed to prioritize continuous availability, a critical

factor for data processing companies.

Our units undergo rigorous testing to ensure reliability and minimize system failures. With

full frontal access, maintenance operations are simplified and can often be performed

without shutting down the unit entirely.

SAVE MAINTENANCE AND

SHUTDOWN TIME

Life is On | Schneider Electric 4

Intelligent Control, Optimal

Performance

Uniflair Small Room Cooling units are equipped with advanced control and management

software developed by Schneider Electric, ensuring optimal performance and reliability.

Every component is monitored in real-time, allowing for proactive maintenance and

efficient operation.

• Intuitive Touchscreen Interface: Easily navigate and control complex operations with

simple commands.

• Intelligent Monitoring: Real-time tracking of system status and performance for optimal

efficiency.

• Predictive Maintenance: Leverage advanced analytics to schedule maintenance and

minimize downtime proactively.

• EcoStruxure Integration: Benefit from continuous monitoring, remote problem-

solving, and predictive analytics for enhanced system management.

Connect

Close the loop

Collect

Connect

everything from

shop floor

to top floor

Convert data into

meaningful

analytics

Capture critical data

at every level, from

sensor to cloud

Drive action through

real-time information

and business logic

5 Uniflair Small Room Cooling

AIR FILTERS

• High efficiency, EU4 pleated air

filters are contained in a metal

frame

• Dirty filter differential pressure

switch

• Low airflow differential pressure

switch

A Closer Look at Small Room

Cooling Units Components

COOLING COIL

• Designed for high sensible heat ratio

(SHR) and reduced pressure drops.

• Made from copper tubes mechanically

expanded on aluminum fins

• Located upstream from the fans and has

a stainless steel condensate drain tray

with a flexible drainage tube and an

integrated siphon.

ELECTRONICALLY COMMUTED EC

FANS

• High-tech compound material

impellers with optimized flow control

• High-efficiency EC motors

• Low power consumption

• High part-load efficiency

FRAME

• Self-supporting frame in galvanized steel

with panels finished in epoxy powders

(color RAL9003).

• Unit access panels equipped with

handles and stainless steel quarter-turn

screws.

CONTROL AND CONNECTIVITY

• 4.3-inch touch-screen connected to the

main board and M172P PLC through an

intermediate device with integrated RJ45

connector.

• Up to 15 units can be linked to each

other through the local LAN network,

optimizing the operation of the units that

are rotated on a time basis.

• Integrated TCP/IP serial card for BMS

connection (SNMP, Modbus TCP/IP or

BACNet/IP)

• Native communication with EcoStruxure

6 Uniflair Small Room Cooling

General

Customize Your Cooling

Solution Optional Features

CONFIGURATION OPTIONS

• A wide range of cooling configurations to give maximum

design freedom and precise control of temperature and

humidity

• Immersed electrode humidifier for modulating steam

production managed by the unit’s microprocessor

• Electrical heaters for a tight control of temperature during

the dehumidification cycle or to bring air temperature up to

set point

• For Chilled Water units , 3 or 2 way valves to guarantee

the value of the air temperature at the condenser outlets

is maintained.

Uniflair Small Room Cooling units offer a wide range of configurable options to

meet your specific needs.

AIR FLOW CONFIGURATION ACCESSORIES

• Suction/discharge plenums to make the airflow pattern

suitable with different site configurations

• Adjustable base frame(200–600mm)for installation with

raised floor

• Bi-directional air discharge grille to be used for upflow

units with non-ducted discharge from above

• Motorized damper (downflow units) to prevent a reverse

flow of air when the unit is not operating

• Active Flow Controller (AFC) Automatically adjusts fan

speed to maintain temperature setpoint by monitoring

underfloor static pressure.

Additional Accessories

• Fire and smoke sensors

• Water leak detector

• Ambient temperature sensor

Life is On | Schneider Electric 7

Dimensions

Uniflair Small Room Cooling

Direct Expansion Air Cooled

SDAV-SUAV

Technical Data

SDAV / SUAV models 0251A1* 0351A1 0601A1

EC fans 1 2 2

Power supply V/ph/Hz 400/3/50Hz

Air flow m3/h 1650 3300 4500

Net Sensible Cooling Capacity1 kW 7,7 13,3 19,6

Net Sensible EER2 3,1 3,4 3,9

Humidification Capacity (Optional) Kg/h 2 2 3

Electric Heaters Absorbed Power

(Optional) kW

2 3 6

*Not available for European market due to F-Gas regulation 1Data refers to nominal conditions , R410A refrigerant with Return air temperature 30°C - 30% RH, Outdoor 35°C 2EER= Net sensible cooling capacity / Room unit absorbed power

SDAV / SUAV models 0251A* 0351A 0601A

Height mm 1740 1740 1740

Length mm 550 850 1200

Depth mm 450 450 450

Coupled with wide range of Remote Air-Cooled Condenser (CAP):

• Efficient heat exchange in a single circuit with copper tubes and aluminum fins.

• Equipped with high-performance AC fans for effective heat rejection.

• Designed for outdoor installation with horizontal or vertical airflow options.

• Operates reliably in outdoor temperatures from +50°C down to -40°C, with dedicated

low temperature kit available for the coldest environments.

8 Uniflair Small Room Cooling

Uniflair Small Room Cooling

Chilled Water

SDCV-SUCV

Technical Data

1Data refers to nominal conditions at Return air temperature 24°C - 50% RH, Water temperature 7/12°C 2Data refers to nominal conditions at Return air temperature 35°C - 30% RH, Water temperature 10/15°C

*Electric Heaters already integrated in the units

8 Uniflair Small Room Cooling

SDCV / SDCV models 0200A1 0400A1 0600A1

EC fans 1 2 2

Power supply V/ph/Hz 400/3/50

Air flow m3/h 1900 3300 4000

Net Sensible Cooling Capacity1 kW 7 12 16

Net Sensible Cooling Capacity2 kW 11 19 25

Humidification Capacity (Optional) Kg/h 2 2 3

Electric Heaters Absorbed Power* kW 4 6 6

SDCV / SUCV models 0200A1 0400A1 0600A1

Height mm 1740 1740 1740

Length mm 550 850 1200

Depth mm 450 450 450

Dimensions

General

Schneider Electric SE

35 rue Joseph Monier

92500 Rueil Malmaison – France

se.com

© 2023 Schneider Electric. All Rights Reserved. Schneider Electric | Life is On, EcoStruxure, Facility Expert, Facility Advisor are trademarks and the property of

Schneider Electric SE, its subsidiaries and affiliated companies

To learn more about Uniflair Room Cooling Solutions contact your Schneider

Electric representative or visit se.com/cooling