Uniflair Small Room Cooling

se.com
High-Performance Cooling
Units for Small Technological
Rooms and Edge Cooling
Applications (5-20 kW)
Uniflair Small Room Cooling
Schneider Electric: Your Partner in Sustainable Data Center Cooling
At Schneider Electric, we are committed to providing innovative and sustainable solutions that help organizations reduce their environmental impact and operational costs.
Our Uniflair Room Cooling units are designed with eco- efficiency in mind, utilizing advanced technologies to minimize energy consumption while maintaining peak performance.
Choose Your Cooling
Technology
Chilled Water units (SDCV-SUCV): Designed to work with a centralized chilled water plant, offering
efficient and scalable cooling solutions for large data centers and facilities.
Direct Expansion Air Cooled units (SDAV-SUAV): Highly efficient mechanical cooling systems,
ideal for small and medium-sized data centers. The units can be coupled with wide range of
remote air-cooled condensers (CAP) and employ to the latest generation of compressors.
Schneider Electric offers a variety of cooling technologies to suit your specific
needs:
3 Uniflair Small Room Cooling
Compact, Efficient, Reliable
Cooling Solutions
Uniflair Small Room Cooling provides a wide range of air intake and delivery configurations
to suit different needs:
Raised Floor Environments: The downflow configuration efficiently distributes cold air into
the floor void, while hot air can be drawn from the bottom or the front.
Server Rooms Without Raised Floors: The upflow configuration is ideal, drawing in hot air
from the front and delivering cold air upwards, either directly into the room or through
the false ceiling.
FLEXIBLE SOLUTIONS
FOR ANY ENVIRONMENT
In critical and edge applications, our cooling system is designed to minimize power
consumption dedicated to cooling the IT load. By optimizing floor space, Uniflair Small
Room Cooling units allow for maximum power allocation to IT equipment and ample
room for IT racks.
With full frontal accessibility and no need for lateral clearance, these units can be
installed in close proximity to each other, reducing the space required for cooling and
expanding the area available for your IT equipment.
MAXIMIZE IT LOAD
AND SAVE SPACE
Uniflair Small Room Cooling units are designed to prioritize continuous availability, a critical
factor for data processing companies.
Our units undergo rigorous testing to ensure reliability and minimize system failures. With
full frontal access, maintenance operations are simplified and can often be performed
without shutting down the unit entirely.
SAVE MAINTENANCE AND
SHUTDOWN TIME
Life is On | Schneider Electric 4
Intelligent Control, Optimal
Performance
Uniflair Small Room Cooling units are equipped with advanced control and management
software developed by Schneider Electric, ensuring optimal performance and reliability.
Every component is monitored in real-time, allowing for proactive maintenance and
efficient operation.
• Intuitive Touchscreen Interface: Easily navigate and control complex operations with
simple commands.
• Intelligent Monitoring: Real-time tracking of system status and performance for optimal
efficiency.
• Predictive Maintenance: Leverage advanced analytics to schedule maintenance and
minimize downtime proactively.
• EcoStruxure Integration: Benefit from continuous monitoring, remote problem-
solving, and predictive analytics for enhanced system management.
Connect
Close the loop
Collect
Connect
everything from
shop floor
to top floor
Convert data into
meaningful
analytics
Capture critical data
at every level, from
sensor to cloud
Drive action through
real-time information
and business logic
5 Uniflair Small Room Cooling
AIR FILTERS
• High efficiency, EU4 pleated air
filters are contained in a metal
frame
• Dirty filter differential pressure
switch
• Low airflow differential pressure
switch
A Closer Look at Small Room
Cooling Units Components
COOLING COIL
• Designed for high sensible heat ratio
(SHR) and reduced pressure drops.
• Made from copper tubes mechanically
expanded on aluminum fins
• Located upstream from the fans and has
a stainless steel condensate drain tray
with a flexible drainage tube and an
integrated siphon.
ELECTRONICALLY COMMUTED EC
FANS
• High-tech compound material
impellers with optimized flow control
• High-efficiency EC motors
• Low power consumption
• High part-load efficiency
FRAME
• Self-supporting frame in galvanized steel
with panels finished in epoxy powders
(color RAL9003).
• Unit access panels equipped with
handles and stainless steel quarter-turn
screws.
CONTROL AND CONNECTIVITY
• 4.3-inch touch-screen connected to the
main board and M172P PLC through an
intermediate device with integrated RJ45
connector.
• Up to 15 units can be linked to each
other through the local LAN network,
optimizing the operation of the units that
are rotated on a time basis.
• Integrated TCP/IP serial card for BMS
connection (SNMP, Modbus TCP/IP or
BACNet/IP)
• Native communication with EcoStruxure
6 Uniflair Small Room Cooling
General
Customize Your Cooling
Solution Optional Features
CONFIGURATION OPTIONS
• A wide range of cooling configurations to give maximum
design freedom and precise control of temperature and
humidity
• Immersed electrode humidifier for modulating steam
production managed by the unit’s microprocessor
• Electrical heaters for a tight control of temperature during
the dehumidification cycle or to bring air temperature up to
set point
• For Chilled Water units , 3 or 2 way valves to guarantee
the value of the air temperature at the condenser outlets
is maintained.
Uniflair Small Room Cooling units offer a wide range of configurable options to
meet your specific needs.
AIR FLOW CONFIGURATION ACCESSORIES
• Suction/discharge plenums to make the airflow pattern
suitable with different site configurations
• Adjustable base frame(200–600mm)for installation with
raised floor
• Bi-directional air discharge grille to be used for upflow
units with non-ducted discharge from above
• Motorized damper (downflow units) to prevent a reverse
flow of air when the unit is not operating
• Active Flow Controller (AFC) Automatically adjusts fan
speed to maintain temperature setpoint by monitoring
underfloor static pressure.
Additional Accessories
• Fire and smoke sensors
• Water leak detector
• Ambient temperature sensor
Life is On | Schneider Electric 7
Dimensions
Uniflair Small Room Cooling
Direct Expansion Air Cooled
SDAV-SUAV
Technical Data
SDAV / SUAV models 0251A1* 0351A1 0601A1
EC fans 1 2 2
Power supply V/ph/Hz 400/3/50Hz
Air flow m3/h 1650 3300 4500
Net Sensible Cooling Capacity1 kW 7,7 13,3 19,6
Net Sensible EER2 3,1 3,4 3,9
Humidification Capacity (Optional) Kg/h 2 2 3
Electric Heaters Absorbed Power
(Optional) kW
2 3 6
*Not available for European market due to F-Gas regulation 1Data refers to nominal conditions , R410A refrigerant with Return air temperature 30°C - 30% RH, Outdoor 35°C 2EER= Net sensible cooling capacity / Room unit absorbed power
SDAV / SUAV models 0251A* 0351A 0601A
Height mm 1740 1740 1740
Length mm 550 850 1200
Depth mm 450 450 450
Coupled with wide range of Remote Air-Cooled Condenser (CAP):
• Efficient heat exchange in a single circuit with copper tubes and aluminum fins.
• Equipped with high-performance AC fans for effective heat rejection.
• Designed for outdoor installation with horizontal or vertical airflow options.
• Operates reliably in outdoor temperatures from +50°C down to -40°C, with dedicated
low temperature kit available for the coldest environments.
8 Uniflair Small Room Cooling
Uniflair Small Room Cooling
Chilled Water
SDCV-SUCV
Technical Data
1Data refers to nominal conditions at Return air temperature 24°C - 50% RH, Water temperature 7/12°C 2Data refers to nominal conditions at Return air temperature 35°C - 30% RH, Water temperature 10/15°C
*Electric Heaters already integrated in the units
8 Uniflair Small Room Cooling
SDCV / SDCV models 0200A1 0400A1 0600A1
EC fans 1 2 2
Power supply V/ph/Hz 400/3/50
Air flow m3/h 1900 3300 4000
Net Sensible Cooling Capacity1 kW 7 12 16
Net Sensible Cooling Capacity2 kW 11 19 25
Humidification Capacity (Optional) Kg/h 2 2 3
Electric Heaters Absorbed Power* kW 4 6 6
SDCV / SUCV models 0200A1 0400A1 0600A1
Height mm 1740 1740 1740
Length mm 550 850 1200
Depth mm 450 450 450
Dimensions
General
Schneider Electric SE
35 rue Joseph Monier
92500 Rueil Malmaison – France
se.com
© 2023 Schneider Electric. All Rights Reserved. Schneider Electric | Life is On, EcoStruxure, Facility Expert, Facility Advisor are trademarks and the property of
Schneider Electric SE, its subsidiaries and affiliated companies
To learn more about Uniflair Room Cooling Solutions contact your Schneider
Electric representative or visit se.com/cooling
Diapositiva 1 Diapositiva 2: Schneider Electric: Your Partner in Sustainable Data Center Cooling Diapositiva 3 Diapositiva 4 Diapositiva 5 Diapositiva 6 Diapositiva 7 Diapositiva 8 Diapositiva 9 Diapositiva 10